본문 바로가기

전동파일

가성비 뛰어난 전동파일, 에지엔도, 에지파일, 프로테이퍼,웨이브원,레시프록,프로글라이더






“Let Us Help You Do Great Root Canals at Half the Cost.”

—Charles J. Goodis, DDS

Endodontist, Albuquerque, NM
Founder & Owner, Edge Endo

Our mission is to deliver endodontic products and solutions, at a substantially lower cost, which in turn benefits practitioners and patients everywhere. Innovation is the heart of Edge Endo®. We are dedicated to the pursuit of bringing leading-edge products to the industry. This thought and modern business model is revolutionizing endodontic practices across the U.S. and the world.

We believe premium technology shouldn’t have to come with a premium price tag. We sell direct to dental professionals, without unnecessary costs, which characterize other endodontic companies and are reflected in inflated prices.

Our commitment is to bring you all the quality, at half the cost.

Proud Supporters of the American Association of Endodontists Foundation

We are proud members of the American Association of Endodontists and support it’s mission and dedication to excellence and quality in the art and science of endodontics and to the highest standard of patient care. EdgeEndo has pledge $375,000 to support the Foundation because we want the profession to continue to thrive with new research that supports the importance of root canal therapy.


2017년 5월!

오스코가 미국 유에스엔도돈틱사의 에지엔도 전동파일을 출시합니다.


Heat Treated Fire-Wire Ni-Ti

 

니켈티타늄 금속의 유연성과 회전에의한 피로 저항성을 극대화한 에지엔도만의 '열처리 및 극저온 처리기술입니다.


1.Long cyclic fatigue

일반 비열처리 전동파일과 비교하여 회전피로도가 최대 8배 강해 내구성이 뛰어납니다.

2. No bounce back

만곡근관시 파일에 가해지는 외측 압력이 적어 치질을 보호하여 트랜스포테이션현상을 최소화합니다.

3.flexible and prebending

유연성이 뛰어나 근관형태에 따라 미리 구부려 사용할 수 있습니다.



에지엔도만의 장점


1.주요시스템과의 호환성

프로테이퍼, 웨이브원(레시프록), 프로글라이더와 호환 됩니다.

2. 뛰어난 가성비

영업조직, 광고 마케팅 비용을 최소화하여 가격이 저렴합니다.


제품소개


1.EdgeFile X1

WaveOne 및 Reciproc과 호환되며 동일한 테크닉과 엔진을 사용합니다.

3개/팩, 할인가 49,500원


2.EdgeTaper Platinum

Protaper와 호환되며 동일한 테크닉과 엔진을 사용합니다.

6개/팩, 할인가 49,500원


3.EdgeGlidePath

Proglider와 호환되며 동일한 테크닉과 엔진을 사용합니다.

4개/팩, 할인가 49,500원



EdgeFile™ with Fire-Wire™ Cyclic Fatigue Testing Study

Introduction

Heat treatment is used to change the deformation and strength characteristics of metals and metal alloys. The purpose of this evaluation was to determine how EdgeEndo’s™ EdgeFile™ with “Fire-Wire™“ NiTi files compared to various competitor NiTi endodontic rotary files performance when tested for cyclic fatigue.

Materials and Methods

EdgeEndo™ EdgeFile™ 20/06 with “Fire-Wire™” rotary files were compared to Dentsply Tulsa Dental® 20/06 Vortex Blue®, Dentsply Tulsa Dental® 20/06 GT Series X®,  Dentsply Tulsa Dental® F1 ProTaper®, Sybron® 20/06 K3®, Sybron® 20/06 K3 XF®, and Brasseler® 20/06 Sequence® Endodontic Files. This study was performed at U.S. Endodontics in Johnson City, TN.

Cyclical Fatigue

Thirty of each file listed above and on the chart in the results portion of this study was evaluated for cyclical fatigue.

Cyclical fatigue test was performed using a custom test system (Fig. 1) with each file rotated at 500 RPM while 3mm of the file tip was inserted in a test block with a 90° curvature. Time to failure (seconds) was measured for each instrument.

Results

Cyclical Fatigue

EdgeFile™ with “Fire-Wire™” rotary files yielded a greater mean time to failure (MTF) than other industry brands

(See Chart below). EdgeEndo™ “Fire-Wire™” files had the greatest mean time to failure at 655.6 seconds, with the lowest MTF at 80.9 seconds.

Figure 2


Dr. Rico Short DMD

Broad Certified Endodontist, Clinical Professor, Apex Endodontics P.C

Dr. Short has published articles in several publications including Dentistry Today, UpScale Magazine, Rolling Out Magazine, and the Journal of Endodontics. The following article is republished with permission from Dr. Rico Short.

Well let’s talk about the elephant in the room.  All files can separate!  If you do enough root canal treatments it will happen to you as well…so relax.  Most of the research shows if the canal was cleaned decently and a working length was established, especially on a vital case, the success rate is still favorable if the separated file is at the apex.(1)  If the file is not at the apex, it should be able to be bypassed or removed.  If any file or other instrument separates inside the canal and can’t be removed, medical-legally, you must inform the patient that an instrument has separated inside the canal.  But you can insure them that the case still should be fine.  A 6 month to a 1 year follow up is generally recommended to make sure there are no issues.  This must be documented in their treatment notes and noted that you also informed the patient.

 

Previous root canal with separated file in the MB root on tooth #14. Patient was then referred to an endodontist.

Previous root canal with separated file in the MB root on tooth #14. Patient was then referred to an endodontist.

Tooth #14 completed showing file removed and MB and MB2 obturated.

Tooth #14 completed showing file removed and MB and MB2 obturated.

There are at least 50 various types of NiTi files on the market.  They are classified according to their design, metal properties, shaping characteristics, breakage potential, and clinical performance.  In addition, most rotary files are non-end cutting. Some files have radial lands for safety and some do not.  Radial lands tend to “slow” the efficiency of the file while keeping it centered for safety. (2)

“The 8 Golden Keys” To Minimize File Separation.

1) Assess Case Complexity

If a case has severe root curvatures or if you see a canal then it disappears in the middle or apical 1/3 then it will be a challenge.  There is probably a bifurcation.  Pick the best rotary file for the job after using handfiles to the working length.

2) Provide Adequate Access

Straight line access and coronal flaring is very important.  It take unnecessary stress off the file.  In addition, the “crown down” method is more efficient than the “step back” . In other words, the rotaries are used from larger to smaller sizes in the “crown down” method.  This allows for better irrigation and less binding of the files. (3)

3) Glide Path

Adequate glide path to the apex is critical before even picking up a nickel titanium rotary file.  Recommend a hand file at the apex to at least a size #15 prior to rotary use.

4) Light Pressure

Use light touch and torque control motor.  Various files cause for different speeds and torque settings.  Refer to the manufactures instructions.  The pressure I recommend is to hold the rotary hand piece like you would hold a very sharp #2 pencil trying not to break the lead tip while writing.

5) Don’t Start Then Stop

Sudden changes in the motion of the file while inside the canal can create unwanted forces on the file.  A smooth gentle motion should be used while inserting and withdrawing the file inside the canals.  I like to use the 5 second rule.  I work a canal with a NiTi file for five seconds or strokes then change to a different file.

6) Lubricate Well

The canals should be lubricated at all times while cleaning and shaping.  Recommend use of sodium hypochlorite in addition to RCPrep (Premier) or Gylde (Dentsply Tulsa).  These agents will create less friction on the files while cleaning and shaping the canals. (4)

7) Check Rotary Files

It is important to evaluate each rotary file before placing it into the canals.  Look for shiny spots or flattened areas.  If you see any of these replace immediately.  Thermal sterilization does not affect fatigue life of the files. (5)

8) Replace Rotary Files

Most manufactures recommend rotary files to be single use.  However, there are some cases in which the file may not contact any dentin or very little.  In these cases, it should be ok to re-use the file.  My golden rule regardless is “Three Strikes” and you are “Out”!

 

What is the perfect rotary file?

So you might ask, what is the perfect rotary file for every single case?  Well the answer is there is no perfect rotary file but there are some better than others.  Many lecturers and manufacturers are always trying to work on and sell the “one file that fits all”.  This is really an impossibility like.  Why?  It’s because ALL canals are different!  The file should not dictate the canal shape.  It’s the canal shape that should dictate the file type and the taper.

For instance, if you have a severely calcified canal, it does not make sense to pull out a .06 taper file.  This will remove unnecessary dentin which can weaken the root or create a vertical root fracture.  In addition, it can also cause a file separation especially if the root is curved.  If the canal is very calcified or have a severe curvature, an .04 taper should be used.

Tooth #31 with a very curved and calcified root canal system with limited access.

Tooth #31 with a very curved and calcified root canal system with limited access.

Tooth #31 cleaned and shaped with Edge File X7 .04 taper.

Tooth #31 cleaned and shaped with Edge File X7 .04 taper.

 

Choosing the Proper Rotary File

I’ve used many types of nickel-titanium rotary files in my over 17 years of practice.  Some were very good at the time and some were not.  However, now Edge Endo has developed some very unique files. one of my favorite files from Edge Endo is the Edge File X7 Universal .04 taper.

It’s strong, flexible, and economical.

These files can be pre-curved to get into difficult and limited access areas.  once they are inside the canal, they follow the canal in a very smooth and silky way. They are also very durable due to their specialized heat treatment process of the nickel titanium.

In conclusion, root canal preparation with NiTi rotaries are very safe and effective.  However, you must choose the proper rotary file for the case.  It demands understanding the root canal anatomy and the usage principles of the select rotary system.  Not just every tooth, but every canal should be evaluation on its own merit regarding length, width, curvature, and apical diameter.  NiTi rotary usage also requires training and proper CE courses.  Following the guidelines above will help the clinician avoid “Separation Anxiety”  as related to endodontic therapy.

References

1) Spili P, Parashos P, Messer HH. The impact of instrument fracture on outcome of endodontic treatment. J Endod 2005; 31: 845−850.

2) Peters OA. Current challenges and concepts in the preparation of root canal systems A review. J Endod 2004; 30:559-97.

3) Leeb J. Canal orifice enlargement as related to biomechanical preparation. J Endod 1983;9: 463-70.

4) Bossler C, Peters OA et al. Impact of lubricant parameter on rotary instrument torque and force. J Endod 2007; 33:280-3.

5) Bergmans, Lars, et al. “Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety.” Am J Dent 14.5 (2001): 324-33.



Dr. Yanina Figueroa

Endodontist, Endodontics of Cobb


The following case study was transcribed from a Skype interview and republished with permission from Dr. Yanina Figueroa. 

A Passion for Endodontics

When colleagues ask her why she decided on Endodontics as a specialty, she responds, “I love the challenge, every person and tooth is different.  There is never a dull moment just a dull bur!”

Dr. Yanina Figueroa’s sense of humor is as sharp as her skills. We understood that after only a few minutes of talking with her.

Growing up in Puerto Rico, she attended public high school, obtained a bachelor’s degree of science in Biology from the University of Puerto Rico-Mayagüez Campus in 2003, and received her D.M.D from the University Of Puerto Rico School Of Dental Medicine in 2007. During her post-graduate years she developed a passion for Endodontics while working as a general Dentist in private practice. Dr. Figueroa materialized her dreams by completing her training in Endodontics in 2013 from The University of Pennsylvania. There she was trained utilizing the newest technology and following the University of Pennsylvania Vision of Excellence in Endodontics.

 

CDszY17UsAESL55

Dr. Yanina Figueroa’s “Beastly Bifurcation,” was featured in the April 2015 DentalTown issue.

We met her when we connected with her on our EdgeEndo® Facebook page. In her constant quest to find the newest and best instruments to tackle her challenging cases, Dr. Figueroa was one of the “early adopters” of the heat-treated EdgeFile®. She is such a fan that she and her “Beastly” case were featured in an EdgeEndo® advertising campaign.

Beastly Bifurcation

By Dr. Yanina Figueroa

I’m an endodontist from Atlanta, Georgia, and I did my specialty at the University of Pennsylvania, graduated 2013 and I wanted to share with you this case of a molar number 14 of a 33 year old patient with irreversible pulpitis and Symptomatic Apical Periodontitis. This case was diagnosed and accessed through the crown using diamond burrs. Then, irrigation with sodium hypochlorite.

10_100635_Pre-op1_.thumb.jpg.f1fc15316516da49c75de9a64e018ae9

“When you see a case like this, you’re wondering to yourself, what file am I going to use for this? How am I going to negotiate that canal without having file breakage?”

First, I tried to get patency of the canals, I did the patency of the distal mesiobuccal canal and distal canal using 10 files, and then worked my way up to a 15 file. I instrumented this case using an SX file to open the orifices, then used copious irrigation with sodium hypochlorite.

I started using the EdgeEndo files utilizing crown down technique, when you see these type of canals that are very curved, you want to flare up a little bit the upper portion of the canal, so your files can slide down easier and have less binding on the walls. I started doing the crown down from a 40 to a 25 and then went all the way to 40’s on the mesiobuccal, on the distal, and I did the palatal to a 45.

I went to a 40 on that root… any other file would have just broken and just could have been impossible to retrieve.

When I took the x-ray to see how the cones were fitting, I noticed that there was a canal missing, so I used the CBCT to find the MB2 canal. All this, of course, while I’m using my EdgeFiles, I used also lube, RC prep for the instrumentation, and I also used a lot of sodium hypochlorite to instrument. Before doing the cone fit, I do irrigation with ultrasonics using sodium hypochlorite , EDTA, and chlorhexidine. I did my cone fit with the Edge Gutta Percha and the AH Plus sealant.

22_100635_Post-op1_.jpg.594bea6a3ca2a7c89be72ad84c54a93c

When I took the x-ray to see how the cones were fitting, I noticed that there was a canal missing…

Now, I can tell you when I took the x-ray I saw that the MB2 was missing, so I took a CT scan and noticed the MB2 and noticed the weird unusual buccal inclination of the MB2 to the palate, and the MB  really pointing towards the buccal. It looked almost like a snake tongue. I was like, oh wow, this has been the thing that I was looking for. I found the MB2 on the second visit. I closed everything up before that with calcium hydroxide, then on the second visit I found MB2.

I proceeded to do the instrumentation up to a 35 on MB2 with the same sequence, using sodium hypochlorite, first of all going up to a number size 15 and doing crown down to a 35. After that, I irrigated everything with sodium hypochlorite, EDTA, chlorhexidine, and I dried everything up with sterile paper points, and took an x-ray with the cone fitting, with cones and age plus sealant.

25_100635_Post-op1_.thumb.jpg.71dd19b0b810af11256aab665b3b1a94

“I haven’t received any endorsement…but this is the only file that could tackle that case.”

After verifying that the diagnostic intermediate x-ray looks fine, I closed everything up using vertical condensation, just leaving 4 millimeters of the apical portion of the cone, and then back filling with Edge Gutta Percha. After that, very important, I always put an orifice barrier. I use purple permaflow orifice barrier, then I put a cotton pellet and that was that.

 

“AAAAAAH the panacea…”

I was trained at U Penn and we believe in large apical sizes and I went to a 40 on that root… any other file would have just broken and just could have been impossible to retrieve. When I did this case I was like “AAAAAAH the panacea.”

The EdgeFiles have been the best files I have used so that is why I am so excited about them.






















제품상담 및 구매 오스코 www.ossco.kr