전동파일

에지엔도 나이타이로터리 파일





에지엔도의 열처리 나이타이 파일은 가격만 착한게 아닙니다. 품질이 좋습니다.


에지엔도의 레시프로케팅 파일인 EdgeFile X1은 뛰어난 유연성으로 근관내에서 Centering 능력이 뛰어나고 근관을 Trasportation시키지 않습니다.




에지파일 X1





J Endod. 2018 Dec;44(12):1788-1791. doi: 10.1016/j.joen.2018.09.011. Epub 2018 Nov 1.

Cone-beam Computed Tomographic Analysis of Canal Transportation and Centering Ability of Single-file Systems.

Hasheminia SM1, Farhad A2, Sheikhi M3, Soltani P4, Hendi SS5, Ahmadi M6.

Abstract

INTRODUCTION:

The purpose of this study was to compare canal transportation and the centering ability of Reciproc (VDW, Munich, Germany), WaveOne (Dentsply Maillefer, Ballaigues, Switzerland), and EdgeFile (EdgeEndo, Albuquerque, NM) rotary systems using cone-beam computed tomographic imaging.

METHODS:

Ninety mesiobuccal mandibular first molar uncalcified canals with at least a 19-mm length, a canal curvature of 15°-30° (the Schneider method), and a mature apex were selected. Canals were randomly divided into 3 groups of 30 teeth, and canal preparation with the Reciproc, WaveOne, and EdgeFile systems was performed according to the manufacturers' instructions. Cone-beam computed tomographic images were taken before and after instrumentation in the same position. Apical transportation was calculated in the distances of 2, 3, and 4 mm from the apex. Kruskal-Wallis and Mann-Whitney U tests were used to statistically analyze the data.

RESULTS:

The mean canal transportation was significantly lower with EdgeFile (P < .001) followed by the WaveOne rotary system. Moreover, the centering ability of the EdgeFile system was higher than that of the WaveOne and Reciproc systems.

CONCLUSIONS:

The EdgeFile rotary system showed the lowest transportation in both the mesiodistal and buccolingual directions and the highest centering ability. The Reciproc system showed the highest transportation and the lowest centering ability.

Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

 

에지엔도 나이타이파일은 Long Oval 형태의 근관에서 세계 유수의 파일 시스템과 비교해도 근관형성능력이 뒤지지 않습니다.


에지테이퍼 앙코어(프로테이퍼 넥스트호환)

X1. X2, X3, X4, X5


에지테이퍼 플래티넘(프로테이퍼 골드호환)



에지엔도의 나이타이 파일은 여러 온도(열)조건에서도 가장 부러지지 않는 파일입니다.






J Endod. 2018 Mar;44(3):489-495. doi: 10.1016/j.joen.2017.09.008. Epub 2017 Dec 19.

Micro-computed Tomographic Evaluation of the Shaping Ability of XP-endo Shaper, iRaCe, and EdgeFile Systems in Long Oval-shaped Canals.

Versiani MA1, Carvalho KKT2, Mazzi-Chaves JF2, Sousa-Neto MD2.

Abstract

INTRODUCTION:

This study evaluated the shaping ability of the XP-endo Shaper (FKG Dentaire SA, La Chaux-de-Fonds, Switzerland), iRaCe (FKG Dentaire SA), and EdgeFile (EdgeEndo, Albuquerque, NM) systems using micro-computed tomographic (micro-CT) technology.

METHODS:

Thirty long oval-shaped canals from mandibular incisors were matched anatomically using micro-CT scanning (SkyScan1174v2; Bruker-microCT, Kontich, Belgium) and distributed into 3 groups (n = 10) according to the canal preparation protocol (ie, XP-endo Shaper, iRaCe, and EdgeFile systems). Coregistered images, before and after preparation, were evaluated for morphometric measurements of the volume, surface area, structure model index (SMI), untouched walls, area, perimeter, roundness, and diameter. Data were statistically compared between groups using the 1-way analysis of variance post hoc Tukey test and within groups with the paired sample t test (α = 5%).

RESULTS:

Within groups, preparation significantly increased all tested parameters (P < .05). No statistical difference was observed in the mean percentage increase of the volume (52%) and surface area (10.8%-14.2%) or the mean percentage of the remaining unprepared canal walls between groups (8.17%-9.83%) (P > .05). The XP-endo Shaper significantly altered the overall geometry of the root canal to a more conical shape (SMI = 2.59) when compared with the other groups (P < .05). After preparation protocols, changes in area, perimeter, roundness, and minor and major diameters of the root canals in the 5 mm of the root apex showed no difference between groups (P > .05).

CONCLUSIONS:

The XP-endo Shaper, iRaCe, and EdgeFile systems showed a similar shaping ability. Despite the XP-endo Shaper had significantly altered the overall geometry of the root canal to a more conical shape, neither technique was capable of completely preparing the long oval-shaped canals of mandibular incisors.

Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

J Endod. 2017 May;43(5):823-826. doi: 10.1016/j.joen.2016.12.026.

The Effect of Temperature on Cyclic Fatigue of Nickel-titanium Rotary Endodontic Instruments.

Dosanjh A1, Paurazas S2, Askar M2.

Abstract

INTRODUCTION:

This study examined the effect of different temperatures on the cyclic fatigue of nickel-titanium rotary files.

METHODS:

Three groups of nickel-titanium rotary files (EF group [EdgeFile; EdgeEndo, Albuquerque, NM], VB group [Vortex Blue; Dentsply Tulsa Dental Specialties, Tulsa, OK], and ESX group [ESX; Brasseler USA, Savannah, GA]) of size 25 with a .04 taper and 25-mm length were tested in a metal block that simulated a canal curvature of 60° and a 5-mm radius curvature. The block was submerged in a water bath filled with water at 3°C, 22°C, 37°C, and 60°C. At each temperature, 30 files from each group were rotated at 500 rpm in the block. The number of cycles to fracture (NCF) was calculated. Statistical analysis was completed using a 1-way analysis of variance with significance at P < .05.

RESULTS:

VB group showed a significant decrease in NCF as the temperature increased from 3°C to 60°C. The ESX group showed a significant decrease in NCF as the temperature increased from 3°C to 37°C. The EF group showed a significant increase in NCF from 3°C to 22°C and a significant decrease in NCF from 22°C to 37°C. For each temperature, the EF group showed higher NCF than the VB group, which showed higher NCF than the ESX group.

CONCLUSIONS:

In this in vitro study, temperature was found to significantly affect the cyclic fatigue of nickel-titanium rotary files. At each tested temperature, NCF was the highest for the EF group followed by the VB group and lowest for the ESX group. Future cyclic fatigue studies should be conducted at body temperature.

Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.